MaltaToday previous editions

MT 24 May 2015

Issue link: https://maltatoday.uberflip.com/i/516462

Contents of this Issue

Navigation

Page 5 of 59

maltatoday, SUNDAY, 24 MAY 2015 6 News CONTINUES FROM PAGE 1 Extracts of the contract have been seen by MaltaToday, and the most sig- nificant part includes the Waiver, which states: "Except as explicitly stated in this Project Closure Agree- ment, the parties will not be liable whatsoever for all and any further, past, present or future concerns, claims or disputes that the parties may have in respect of the Amend- ed Main Agreement and each Party waives with binding effect all its rights in relation to the Amended Main Agreement except in relation to those rights explicitly stated in this Project Closure Agreement." The Project Closure Agreement defined specifically the claims that were being made by Skanska and the government. No reference was made to the quality of the cement or concrete used at the hospital or to any other design and construction deficien- cy. Contacted by MaltaToday, former health minister John Dalli, who in 2009 was the minister po- litically responsible for the FMS, told MaltaToday that he couldn't remember the details of the con- tract. He however confirmed that the two sides had reached an overall agreement to wash out the claims that were being put forward. "I remember that there were a lot of claims: from our end the gov- ernment was complaining over the delays and there were fines which they had to pay; they also had some claims," Dalli said. "I don't have the facts in hand but I think we had agreed on a fixed sum for the works on the hospital to go while the claims were washed out." Dalli added that the agreement had undergone the usual process where it was presented to Cabinet and approved. Corroborating Dalli's comments, former finance minister Tonio Fenech – who was responsible for the FMS prior to a change in port- folio – confirmed that issues had arisen between the two sides and were sorted out through the 2009 agreement. In view of the technical report that confirmed structural damage at Mater Dei Hospital, Fenech said that no contract was above the Maltese law and responsibility still had to be shouldered by architects and contractors irrespective of any agreement that could have been reached. He went on to add that any prob- lems relating to concrete should have been identified in 1996 "when Alfred Sant had commissioned an architectural firm to test the concrete and a decision was then taken by Sant to increase the hos- pital's floors". Seismic risk from weak concrete The extract exonerating local and foreign companies from responsi- bility for any claim came as a shock to those investigating works at the public hospital that cost the Mal- tese taxpayer €600 million. Effectively it could exonerate Skanska and its Maltese partners Blokrete and all other technical as- sistance or supplies from any de- sign or construction defect. Independent technical consult- ants ARUP this week confirmed that the Accident and Emergency Department was constructed with inferior quality cement. In some cases, they said that the cement work placed certain parts of the hospital in a very vulnerable status if certain seismic activities were to occur in the area. The FMS contract with Skanksa had been signed off by architect Paul Camilleri on behalf of the Foundation for Medical Services (FMS) in 2009. MaltaToday could not confirm what had led the government to instruct Camilleri to include this amendment in the contract, and whether this was a Cabinet deci- sion to include the waiver. At the time, the acting CEO of the FMS was Brian St John, who took up his post in September 2008 after leaving Lawrence Gon- zi's secretariat. He now serves as CEO to the Nationalist party. On his part, St John referred MaltaTo- day to former minister John Dalli when asked for his comment. On Thursday, energy and health minister Konrad Mizzi said that concrete strength of the Accident and Emergency (A&E) and Block D buildings at Mater Dei Hospital were found to be "low and below specification". A second inquiry into the civil and criminal liability of hospital engineers Skanska, of Sweden, has also been finalised by retired judge Philip Sciberras. Arup's inspection gave assur- ance that the A&E building was currently structurally sound to safely function on an ongoing op- erational basis. Independent con- crete core tests identified that the samples included both hard and softer limestone aggregate, with high porosity and high levels of carbonation. "This was consistent with ob- served corrosion of reinforcing steel to columns in untreated un- dercroft zones," Arup director Andrew Harrison said during a presentation of their findings at the Mater Dei auditorium. Harrison admitted that Mater Dei's structural situation was in- comparable to other hospitals he has seen. "The extent of the problem at Mater Dei is surprising and dis- appointing," Harrison said. "It is highly unusual for concrete strength issues to exist in hospitals in this day and age." The hospital blocks were de- signed to have a concrete cube strength of 30 megapascals (MPa). Yet the A&E block was found to have a concrete strength of only 18 MPa, while that of Block D only hit 23 MPa. Block A (29 MPa) and Block B (27 MPa) fell narrowly below their specified strength, while Block C, Block E, the mortuary and the on- cology hospital were on target. The impact of the "below-spec- ification concrete" was assessed using a structural model of the building, to test the seismic resil- ience of the A&E building. Arup's assessment highlighted that reme- dial measures were required to ad- dress performance under seismic conditions. Arup are currently finalising re- medial designs for the A&E build- ing and the requirements will shortly be issued for contractor/s to deliver the works. Remedial works will include reconfiguration of roof plant rooms to reduce loads together with new bracing, the introduction of additional shear walls to pro- vide enhanced stability, concrete repairs to poor condition columns and verification of ties to the ex- ternal façade. The remedial works design of Block D and the structural design assessment of Block F are ongo- ing. Arup has forecast that all reme- dial works will be completed by the end of 2016. Mater Dei's structural problems were identified back in August last year, after government-appointed contractors were asked to carry out tests on the building's columns and infrastructure. The tests were carried out as part of the government's plan to build a floor above the A&E building, creating space for an additional 68 beds. Following the tests, the government identified a site across the road from the emergency de- partment as an alternative for the new ward. Fears that hospital blocks may not withstand seismic activity Konrad Mizzi said the government has written to Skanska about Arup's findings, and called for an urgent meeting

Articles in this issue

Archives of this issue

view archives of MaltaToday previous editions - MT 24 May 2015